Pioneer LE Top
Vent Our #1 selling coal stoker stove.
The Pioneer LE Top Vent stove with its attractive styling, brass
pins, brass handles and ornamental top door will make for a welcome
addition in any den or family room. Using the technology that goes
into all Leisure Line Stoves, the virtually indestructible feeder
system has put this unit head and shoulders above all others. Built
with all the latest innovations, the LE can produce up to 90,000
BTU’s input and can be vented with a chimney or by the use of the
power vent system. Digital Coal-trol thermostat
controlled heat always maintains the temperature you
desire. Fan speeds from 35 CFM’s to 265 CFM’s are
regulated by our thermostat. Set it and forget it.
Without a doubt, this stoker was built with the homeowner in
mind in every way. |
Specs:
5,000 – 90,000 BTU Input, Height 38”, Depth 31”, Width
27”, Hopper Capacity 110 lbs, 6” Top Vent Flue, Weight 250
lbs. Options:
Domestic hot water coil |
 |
Pioneer LE Back
Vent Our Pioneer LE Back Vent comes
standard with everything you would want in a quality stoker stove.
Smooth and quiet operation is what you can expect from our LE with
a unique feeder system second to none. Our back vent LE model can
be used in low flue chimneys or can be power vented directly out
the back so no pipe will be seen. The ornamental top door and
hefty cast iron bottom door along with our digital, programmable
Coal-trol thermostat are standard items. With the innovative style
of our Pioneer LE, it no longer looks or operates like your
grandfather’s coal stove. |
Specs:
5,000 – 90,000 BTU Input, Height 38”, Depth 31”, Width 27”, Hopper
Capacity 110 lbs, Blower adjusts from 35 CFM’s to 265 CFM’s, 6”
Back Vent Flue, Weight 250 lbs. Options: Domestic hot water coil |
 |
Pocono Top
Vent The Pocono, specially engineered
for the cold winters in the Pennsylvania Mountains. This basement
unit was built with the homeowner in mind. Extra thought was given
when designing this unit to hold 200 lbs of rice coal for extended
periods of hard burning. Heavy gauge galvanized steel is used in
the construction of the large ash tub. The body of the unit is
manufactured from durable 12-gauge steel to radiate the heat being
produced by the 90,000 BTU burner. Large dual blowers built into
the double wall air shroud will wash the stove clean of heat so no
hot spots exist on this unit. Digital, programmable
Coal-trol thermostat standard. |
Specs:
5,000 – 90,000 BTU Input, Height 47”, Depth 33”, Width 24”, Hopper
Capacity 200 lbs, Dual 265 CFM blowers, 6” Top Vent Flue,
Weight 300 lbs Options: Domestic
hot water coil, 12" duct top or special order hot air jacket with
or without 12" duct fan |
 |
Pocono Back
Vent The Pocono, specially engineered
for the cold winters in the Pennsylvania Mountains. This basement
unit was built with the homeowner in mind. Extra thought was given
when designing this unit to hold 200 lbs of rice coal for extended
periods of hard burning. Heavy gauge galvanized steel is used in
the construction of the large ash tub. The body of the unit is
manufactured from durable 12-gauge steel to radiate the heat being
produced by the 90,000 BTU burner. Large dual blowers built into
the double wall air shroud will wash the stove clean of heat so no
hot spots exist on this unit. Digital, programmable Coal-trol
thermostat standard. |
Specs: 5,000 – 90,000 BTU Input, Height 47”,
Depth 33”, Width 24”, Hopper Capacity 200 lbs, Dual 265 CFM
blowers, 6” Top Vent flue, Weight 300 lbs. Options: Domestic
hot water coil, 12" duct top or special order hot air jacket with
or without 12" duct fan |
 |
Hearth When considering a stoker model to
set in front of your existing fireplace, look no further then a
Leisure Line Hearth Stoker Stove. This unit is a mirror image of
our Pioneer stove, but with the hopper and feeder mounted on the
side for easy access. All the fine qualities of our stove are built
into our Hearth Stoker. Digital Coal-trol thermostat and
large ash pan are standard. The Hearth, like all Leisure Line
Stoves is low maintenance and high BTU. |
Specs: 5,000 – 90,000 BTU Input, Height 33.5”,
Depth 21”, Width 39”, Hopper Capacity 70 lbs, 212 CFM blower, 6”
Back Vent flue, Weight 232 lbs, Hearth Depth w/o Front Support
14”. Options: Right or left side mount
hopper |
 |
Hyfire II Leisure Line’s maximum in home
heating. This unit is the same as the Hyfire I, but with twin
90,000 BTU burners. Heat ranges from 5,000-180,000 BTU’s
can be expected with this unit. If you’re the person who wants the
most from their heating dollar, then the Hyfire II is the one
for you. Both Hyfire stoves can be ducted directly to an existing
hot air furnace. |
Specs: 5,000 – 180,000 BTU’s, Height 46”,
Depth 33” (includes hopper), Width 29.5”, Hopper Capacity 200
lbs, 530 CFM blower (twin 265 CFM), 6” Back Vent
flue, Weight 400 lbs. Options: Domestic
hot water coil, 12" duct top and hot air jacket with or without 14"
duct fan |
 |
Hot Air
Jacket The optional Air Jacket pictured
here fits either the Hyfire I or the Hyfire II. This unit can be
piped directly into your existing hot air system. A great
supplemental heating source will cut into those high heating bills.
The Hyfire jacket does not come with filters or a cold air
return. Along with this stove option,
there are other options mentioned in the descriptions of the other
stoves in this brochure. Many of these can be added to any stove.
If you have ideas or questions regarding the customization of your
Leisure Line Stove, please ask! |
|
|
 |
Econo I This finely crafted automatic coal
stove can be just what you’re looking for to cut you high energy
bills. Designed as a great little supplemental heating source, the
Econo I will take the chill off any winter morning. Built with the
strict codes of the Leisure Line Stoves, but priced under
comparison stokers in today’s market, this 70,000 BTU unit is a
great heater. Rated as on of the most cost-effective stokers being
built today. Ask your dealer about the Econo I, you’ll be glad you
did! |
Specs: 4,500 – 70,000 BTU Input, Height 33.5”, Depth 27”, Width 20”, Hopper Capacity 60 lbs, Blower 110 CFM, 6” Back Vent flue, Weight 200 lbs. Options: Domestic hot water coil |
 |
Econo
Sidewinder Our Sidewinder can be just the
small stoker stove you have been searching for. With the
credentials of our Econo I, but with the feeder and hopper mounted
on either side, this little unit will fit into small tight spaces.
Since the hopper is mounted on the side, this stoker will take up
very little space when backed against a non-combustible
wall. |
Specs: 4,500 – 70,000 BTU’s, Height 33.5”, Depth 18”, Width 33”, Hopper Capacity 60 lbs, Blower 110 CFM, 6” Back Vent flue, Weight 200 lbs. Options: Domestic hot water coil ALL UNITS COME STANDARD IN BLACK. ADDITIONAL COLOR OPTIONS INCLUDE HONEY GLO BROWN, FOREST GREEN, AND SLATE BLUE |
Leisure Line Stoker Stoves Power Draw
Feeder Motor - .55amps Combustion Fan - .58amps Convection Fan - 1.86amps Power Venter - 1.77 amps or 136 watts
Also for use in mobile homes. Model: Econo I, Econo Sidewinder, Hearth, Pioneer LE TV or BV, Pocono TV or BV, Hyfire I and Hyfire II Fuel: Rice Coal
U. S. Environmental Protection Agency This heater is only for burning coal. Use of any other solid fuel except for coal ignition purposes is a violation of Federal Law.
Conam Inspection, Inc., Auburn, Ma 01501 Stl-Oc2
Tested 8/96 (Hyfire Tested 12/96) to ANS1/UL 1482, CSA B366-M1979
Chimney Type: Minimum 6-inch diameter approved low heat, residential-type, all fuel - chimney. Connector: 6-inch diameter, 24-gauge blue or black steel install at least 18 inches from ceiling. Special methods are required when passing through a wall or ceiling. See instructions and building codes. See instruction manual for mobile home installation. |
Install with
Minimum Clearance to wall as shown (in inches). | | A | B | | Pocono | 21" | 12" | | Pioneer | 22-1/2" | 12" | | Hearth | 27" | 12" | Econo Sidewinder Econo 1 | 27" 21" | 12" 12" | | Hyfire I | 26" | 16" | | Hyfire II | 30" | 20" |
|
 |
 |
Leisure Line Stoves generate heat
through combustion of fuel. The heat is transferred through the
heat exchanger and distributed to the conditioned room. The
products of combustion, however, must be vented safely out of the
structure. In a conventional chimney, venting is achieved by the
natural lifting action of the hot combustion gas. New, efficient
systems absorb more of the heat in the heat exchanger and produce
lower temperature vent gas. Lower temperature gas does not rise as
quickly or as reliably as in older, less efficient systems. A power
venter uses a motorized blower to vent the products of combustion.
A power venter is interlocked with the appliance to ensure that
proper draft is achieved. |
 |
The SWG combines the motor,
blower, and vent hood in one complete, easy to install unit. The
SWG mounts on the outside of the building and pulls the combustion
gas from the appliance through the outside wall utilizing 100%
negative pressure. Benefits of the SWG Power Venter
include: 100% Negative pressure in the
vent pipe for maximum safety. No need to seal vent pipe
joints, saving time and money. Significantly longer vent
lengths than positive pressure, direct vent systems. The SWG is recommended by major
heating appliance manufacturers.
|
 |
Specifications:
| Model | Volts | Hz | Amps | Watts | RPM
| Thermal
Protect. | A | B | C | D | E | F | SWG-4HDs | 115 | 60 | 1.7 | 138 | 3000 | Yes | 4" | 6" | 11
3/4" | 9 1/2" | 11" | 11
1/2" |
|
 |
Planning the Venting
System Location of the termination of the
venting system should comply with the National Fuel Gas Code,
A.N.S.I. Z223.1, manufacturer's recommendations and/or applicable
local codes. See Diagram for typical terminal locations.
The exit termination of a mechanical draft
system must not be less than 7' above grade when located adjacent to a public
walkway. The vent termination of a direct vent or
sealed combustion appliance with an input of 50,000 BTU's per hour or less must
be located at least 9" from any opening through which vented gases could enter the building. With an input over 50,000 BTU's per hour, a 1' termination clearance is required. Another term for
direct vent is sealed combustion. The venting systems with the exception of
direct vent appliances, must terminate at least 4' below, 4' horizontally, or 1' above any door, window or gravity air inlet into the
building. The bottom of the vent terminal must be
located at least 1' above finished grade. A venting system must terminate at least 3'
above any forced air inlet located within 10'. The vent termination point must not be
installed closer than 3' from an inside corner of an L-shaped structure. The vent termination should not be mounted
directly above or within 3' horizontally from an oil tank vent or
gas meter, (not shown)
|
Clearance to Combustible
Material If mounting the venting system
near combustible materials, refer to Diagram A for allowable
installation clearances. Clearances are based on an installation
using single wall steel vent pipe. If manufactured double wall vent
pipe is required or used for the installation, clearance should be
based on the vent pipe's rated clearance. Always check local code
requirements for code restrictions.
Routing of the vent system and clearances for the vent pipe may be
planned once the termination location is determined. Route the vent
pipe from the stove to the venter using as few elbows as possible.
The horizontal section of the vent pipe should have a slight upward
slope from the stove to the venter. The vent pipe size (diameter)
can be smaller than a typical chimney vented system and still
overcome the higher pressure losses because the power venter
mechanically creates the required draft or airflow to vent the
system. |
Single Pipe
System | Allowable Inlet
Temperature | Clearance
(B) | | 400°F or
less | 12" min. | | 550°F or less
| 12" min. | Insulated Double Pipe
System | Allowable Inlet
Temperature | Clearance
(A) | | 400°F or
less | 2.5"
min. | | 550°F or
less | 2.5"
min. |
|
 |
Extension
Kits The standard SWG Power Venter is
designed for walls up to 8" thick. PEK extension kits allow the SWG
to be installed into walls up to 16" thick. The PEK kit includes
the inner/outer pipe extension and air flow damper.
Power
Venter Model | Extension
Kit Model | SWG -
4HD | PEK -
4 |
|
Offers
quality coal stoves, stoker stoves, coal burning stoves, coal
stoves, and Leisure line coal stoves for clean, inexpensive heating
for your home. |
|
|
|
|
|
 |